Home View Cart Contact Us Sitemap Order Status

Access Control
Alarm Monitoring
Alarm System FAQ
Anti-Theft Devices
Audio Monitoring - Louroe
Biometrics
Burglar Alarm System Packages
Burglar Alarm Systems
CCTV Video Surveillance
Central Station Equipment
Central Vacuum
Document Center
Driveway Alarms
Entertainment Systems
Extreme CCTV
Fiber Optics
Fire Alarm Systems
Gas Detectors & Alarms
GE Security
Home Automation
Intercom Systems
Locksmith Supplies
Marine Alarms
On-Q Home
Other Stuff
Power Supplies
Professional Audio
Sensors and Detectors
Sirens, Strobes & Horns
Structured Wiring
Telephone Systems
Tools & Test Equipment
Warrantees
Wire & Cable
Z-Wave Home Automation
Discontinued Products
Shop by Brand

Shop by Brand > ACT Solutions > ACT - Applied Control Technologies

ACT - Applied Control Technologies

ACT AC100 120VAC, 5A, Choke
ACT AC100 120VAC, 5A, Choke

ACT AC100 120VAC, 5A, Choke

The AC100 is an HID choke intended for use with any PCC receiver where transient spikes from HID ballast may interfere with PCC command signals to the receivers.


ACT AF100 120VAC, 5A, 40:1, Plug-In Filter Module
ACT AF100 120VAC, 5A, 40:1, Plug-In Filter Module

ACT AF100 120VAC, 5A, 40:1, Plug-In Filter Module

The AF100 is a passive plug in filter for 120 volt appliances generating electrical noise.


ACT AF120 120VAC, 15A, 30:1, Plug-In Filter Module
ACT AF120 120VAC, 15A, 30:1, Plug-In Filter Module

ACT AF120 120VAC, 15A, 30:1, Plug-In Filter Module

The AF120 is a 30:1 passive filter designed to prevent noise in the 120kHz range (created by the load) from interfering with Powerline Carrier transmissions on the powerline. The AF120 is a high-pass and a lowpass filter. Frequencies less than 80kHz and greater than 200kHz are allowed to pass through the circuit relatively unaffected. However, frequencies within 80kHz to 150kHz, are attenuated significantly.


ACT AF300 120VAC-277VAC, 20A, Low Pass Filter
ACT AF300 120VAC-277VAC, 20A, Low Pass Filter

ACT AF300 120VAC-277VAC, 20A, Low Pass Filter

The AF300 is a Line Isolation Filter which filters out PCC command signals and any strong electric clutter at 120 kHz on the AC line. It provides attenuation at a 40:1 ratio input to output respectively. It prevents passage of the PCC command signals or 120 kHz electronic noise from the line side (primary) to the load side (secondary) and vice versa. The AF300 has 3 wires, and is rated 20 Amps for applications up to 277 volts.


ACT AF310 120VAC-277VAC, Band Pass Filter
ACT AF310 120VAC-277VAC, Band Pass Filter

ACT AF310 120VAC-277VAC, Band Pass Filter

The AF310 is a Line Noise Attenuator which is parallel tuned and, therefore, attenuates noise and unwanted signals of frequencies above or below 120 kHz without attenuating the PCC signal. It attenuates spikes and transients having rise times which are too fast to be affected by conventional spike suppressors. The AF310 is a 2 wire device and is rated up to 277 VAC.


ACT AS101A 120VAC, 3&4-Way Aux Multi-Switch, Almond (Special Order)
ACT AS101A 120VAC, 3&4-Way Aux Multi-Switch, Almond (Special Order)

ACT AS101A 120VAC, 3&4-Way Aux Multi-Switch, Almond (Special Order)

Companion (Slave) switch for use with ZDW103/ZRW103 or ZRW153 in 3-way or 4-way circuits. Up to 2 companion switches may be installed. If more are needed, use a ZDW103 as a transmitter and associate it with the switch connected to the load. HomeSeer can set up the association, or use a ZTH100 remote.


ACT AS101I 120VAC, 3&4-Way Aux Multi-Switch, Ivory
ACT AS101I 120VAC, 3&4-Way Aux Multi-Switch, Ivory

ACT AS101I 120VAC, 3&4-Way Aux Multi-Switch, Ivory

Companion (Slave) switch for use with ZDW103/ZRW103 or ZRW153 in 3-way or 4-way circuits. Up to 2 companion switches may be installed. If more are needed, use a ZDW103 as a transmitter and associate it with the switch connected to the load. HomeSeer can set up the association, or use a ZTH100 remote.


ACT AS101W 120VAC, 3&4-Way Aux Multi-Switch, White
ACT AS101W 120VAC, 3&4-Way Aux Multi-Switch, White

ACT AS101W 120VAC, 3&4-Way Aux Multi-Switch, White

Companion (Slave) switch for use with ZDW103/ZRW103 or ZRW153 in 3-way or 4-way circuits. Up to 2 companion switches may be installed. If more are needed, use a ZDW103 as a transmitter and associate it with the switch connected to the load. HomeSeer can set up the association, or use a ZTH100 remote.


ACT AT001 A10, 120VAC, Test Transmitter

ACT AT001 A10, 120VAC, Test Transmitter



ACT AT004 A10, 120VAC-277VAC, Master Multi-Tester and Programmer
ACT AT004 A10, 120VAC-277VAC, Master Multi-Tester and Programmer

ACT AT004 A10, 120VAC-277VAC, Master Multi-Tester and Programmer

The AT004 is an X10 Transceiver, able to send and receive A10 enhanced or standard X10 signals. Keypad selections enable selection of transmit signal levels, single or continuous signal transmission, user selection of zero crossing degree shift and display or log the level of noise or signal on the power line on AT004's Liquid Crystal Display (LCD).


ACT CA000 120VAC-277VAC, Signal Coupling Amplifier

ACT CA000 120VAC-277VAC, Signal Coupling Amplifier

This is NOT the same as a coupler-repeater. It is used in very specialized applications. Please call for technical assistance before ordering.



ACT CA200 240VAC, Signal Coupling Amplifier, International Version (Special Order)

ACT CA200 240VAC, Signal Coupling Amplifier, International Version (Special Order)

This is NOT the same as a coupler-repeater. It is used in very specialized applications. Please call for technical assistance before ordering.



ACT CP000 120VAC-277VAC, Passive Coupler
ACT CP000 120VAC-277VAC, Passive Coupler

ACT CP000 120VAC-277VAC, Passive Coupler

This device installs at the circuit breaker panel, and acts as a bridge between the two phases of 120V power present at the panel. This gives the signals an easier path to travel, and improves reliability.


ACT CP010 120VAC-277VAC, 10:1 Ratio, Passive Coupler

ACT CP010 120VAC-277VAC, 10:1 Ratio, Passive Coupler



ACT CP020 120VAC-277VAC, 6:1 Ratio, Passive Coupler

ACT CP020 120VAC-277VAC, 6:1 Ratio, Passive Coupler



ACT CP400 480VAC, Passive Coupler

ACT CP400 480VAC, Passive Coupler



ACT CR134 A10, 120/208VAC, 3-Phase Coupler Repeater
ACT CR134 A10, 120/208VAC, 3-Phase Coupler Repeater

ACT CR134 A10, 120/208VAC, 3-Phase Coupler Repeater

The CR134 and CR334 are A10 enhanced powerline carrier coupler repeaters for distributing Powerline Control signals to all phases of power. Both have DIP switches that enable the user to customize their operation depending on the application. Both are housed in a grey painted enclosure that is designed to mount on a 4-11/16" by 4-11/16" electrical box. LED's in the cover indicate operational modes.


ACT CR230 120/240VAC, Split-Single Phase, Basic Coupler Repeater

ACT CR230 120/240VAC, Split-Single Phase, Basic Coupler Repeater



ACT CR234 A10, 120/240VAC, Split-Single Phase, Coupler Repeater

ACT CR234 A10, 120/240VAC, Split-Single Phase, Coupler Repeater



ACT CR244 A10, 240/415VAC 3-Phase Coupler Repeater, 50 Hz, Int'l. (Special Order)

ACT CR244 A10, 240/415VAC 3-Phase Coupler Repeater, 50 Hz, Int'l. (Special Order)



ACT CR254 A10, 120/208/240VAC "High Leg" Coupler Repeater (Special Order)

ACT CR254 A10, 120/208/240VAC "High Leg" Coupler Repeater (Special Order)

This is a very specialized coupler-repeater designed especially for use in PCC (X-10) installations powered by a "High-Leg" Delta transformer. Please call for tech assistance before ordering.



ACT CR334 A10, 277/480VAC 3-Phase Coupler Repeater
ACT CR334 A10, 277/480VAC 3-Phase Coupler Repeater

ACT CR334 A10, 277/480VAC 3-Phase Coupler Repeater

The CR134 and CR334 are A10 enhanced powerline carrier coupler repeaters for distributing Powerline Control signals to all phases of power. Both have DIP switches that enable the user to customize their operation depending on the application. Both are housed in a grey painted enclosure that is designed to mount on a 4-11/16" by 4-11/16" electrical box. LED's in the cover indicate operational modes.


ACT RB104 A10, 120/208VAC, 30A, SPDT Relay Receiver
ACT RB104 A10, 120/208VAC, 30A, SPDT Relay Receiver

ACT RB104 A10, 120/208VAC, 30A, SPDT Relay Receiver

The RB104 Unit is an A10 enhanced 120/208 VAC, 50/60 Hz, powerline carrier receiver controlling a single remote Form C Relay capable of switching a 30 amp load. The RB104 will continuously monitor the powerline for PCC signals, and adjust its gain to filter out line noise. The RB104 will close or open its relay via Standard or Extended X10 command. The RB104 may be remote controlled by addressing it by its base address or its sub address, or through groups by the commands ALL LIGHTS ON, ALL LIGHTS OFF, or ALL UNITS OFF. These global commands must be configured. The RB104 will transmit the current relay status when requested. The RB104 has an external override input. Two wires connect to this input. When the wires make contact, the relay is turned on. When the wires break contact, the relay is turned off. The RB104 also has a mode switch to allow the user to gain manual control of the relay. ON position turns the relay on, OFF position turns the relay off and AUTO position allows the software to control the relay. The RB104 may also be configured to remember its relay state upon power up. The RB104 may be configured with a "time-out" feature, where the state the relay reverts to ON or OFF after a specified period of time.


ACT RB204 A10, 240VAC, 30A, SPDT Relay Receiver
ACT RB204 A10, 240VAC, 30A, SPDT Relay Receiver

ACT RB204 A10, 240VAC, 30A, SPDT Relay Receiver

The RB204 Unit is an A10 enhanced 240 VAC, 50/60 Hz, powerline carrier receiver controlling a single Form C Relay, capable of switching a 30 amp load.


ACT RB304 A10, 277/480VAC, 30A@277 or 15A@480, SPDT Relay Receiver
ACT RB304 A10, 277/480VAC, 30A@277 or 15A@480, SPDT Relay Receiver

ACT RB304 A10, 277/480VAC, 30A@277 or 15A@480, SPDT Relay Receiver

The RB304 Unit is an A10 enhanced 277/480 VAC, 50/60 Hz, powerline carrier receiver controlling a single remote Form C Relay capable of switching a 30 amp load.


ACT RB310 277VAC, 20A, SP, Receiver w/o "All Lights On"

ACT RB310 277VAC, 20A, SP, Receiver w/o "All Lights On"



ACT RD124 A10, 120VAC, 300 Watt, Plug-In Dimmer
ACT RD124 A10, 120VAC, 300 Watt, Plug-In Dimmer

ACT RD124 A10, 120VAC, 300 Watt, Plug-In Dimmer

The RD124 is an A10 enhanced powerline carrier dimming receiver. Unit responds to On, Off, Bright, Dim, All Lights On, AllLights Off and All Units Off.

A10 circuitry remembers last dim level for restoration of dim level upon power up. A lamp plugged into the RD124 aids in configuring the unit address.

The RD124 is programmable to any of 256 addresses, and up to 4 relative scenes. The dimmer has 16 steps over the entire dimming range (64 steps with Extended Code, 32 steps with Preset Dim code).


ACT RD134A A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Almond (Special Order)
ACT RD134A A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Almond (Special Order)

ACT RD134A A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Almond (Special Order)

The RD134 is an A10 enhanced powerline carrier dimming receiver. The RD134 responds to ON, OFF, BRIGHT, DIM, and can be configured to respond to ALL LIGHTS ON, ALL LIGHTS OFF, ALL UNITS OFF, and STATUS REQUEST. Dimmer remembers last dim level for correct status report and restoration of dim level upon power up. Dimmer can also be configured to respond immediately to ALL LIGHTS ON and ALL UNITS OFF.

The RD134 is programmable to any of the 256 addresses, and for up to 64 relative scenes and 4 global scenes. The fade rate of the dimmer can be programmed from immediate to 271 seconds over the entire dimming range, with 3.12 seconds being the default setting.

Most of the wall-Mount units are stocked in White (W) and Ivory (I), however, "Almond" is usually only available in large quantities, special order. Call for quote and lead-time.



ACT RD134I A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Ivory
ACT RD134I A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Ivory

ACT RD134I A10, 120VAC, 300 Watt, Wall-Mount Dimmer, Ivory

The RD134 is an A10 enhanced powerline carrier dimming receiver. The RD134 responds to ON, OFF, BRIGHT, DIM, and can be configured to respond to ALL LIGHTS ON, ALL LIGHTS OFF, ALL UNITS OFF, and STATUS REQUEST. Dimmer remembers last dim level for correct status report and restoration of dim level upon power up. Dimmer can also be configured to respond immediately to ALL LIGHTS ON and ALL UNITS OFF.

The RD134 is programmable to any of the 256 addresses, and for up to 64 relative scenes and 4 global scenes. The fade rate of the dimmer can be programmed from immediate to 271 seconds over the entire dimming range, with 3.12 seconds being the default setting.

Most of the wall-Mount units are stocked in White (W) and Ivory (I), however, "Almond" is usually only available in large quantities, special order. Call for quote and lead-time.



ACT RD134W A10, 120VAC, 300 Watt, Wall-Mount Dimmer, White
ACT RD134W A10, 120VAC, 300 Watt, Wall-Mount Dimmer, White

ACT RD134W A10, 120VAC, 300 Watt, Wall-Mount Dimmer, White

The RD134 is an A10 enhanced powerline carrier dimming receiver. The RD134 responds to ON, OFF, BRIGHT, DIM, and can be configured to respond to ALL LIGHTS ON, ALL LIGHTS OFF, ALL UNITS OFF, and STATUS REQUEST. Dimmer remembers last dim level for correct status report and restoration of dim level upon power up. Dimmer can also be configured to respond immediately to ALL LIGHTS ON and ALL UNITS OFF.

The RD134 is programmable to any of the 256 addresses, and for up to 64 relative scenes and 4 global scenes. The fade rate of the dimmer can be programmed from immediate to 271 seconds over the entire dimming range, with 3.12 seconds being the default setting.

Most of the wall-Mount units are stocked in White (W) and Ivory (I), however, "Almond" is usually only available in large quantities, special order. Call for quote and lead-time.



ACT RD161 120VAC, 500W, SP, 3-Way or Single Inductive Dimmer, White & Ivory

ACT RD161 120VAC, 500W, SP, 3-Way or Single Inductive Dimmer, White & Ivory

Looking for an easy way to automate low-voltage lighting and motor loads such as ceiling fans? You've found it. This inductive dimmer switch gives you the power to control low-voltage lights, ceiling fans and other inductive devices locally at the switch or remotely from any X10 transmitter.


ACT RD224 A10, 230VAC, 300 Watt, Plug-In Dimmer, Euro (Special Order)

ACT RD224 A10, 230VAC, 300 Watt, Plug-In Dimmer, Euro (Special Order)



ACT RF124 A10, 120VAC, 20A, Fixture Module, Isolated Contact
ACT RF124 A10, 120VAC, 20A, Fixture Module, Isolated Contact

ACT RF124 A10, 120VAC, 20A, Fixture Module, Isolated Contact

The RF124, RF204 and RF304 are A10 enhanced powerline carrier receivers controlling a single remote Form C Relay capable of switching a 30 amp load.

The RF124, RF204 and RF304 will continuously monitor the powerline for PCC signals, and adjust their gain to filter out line noise. They will close or open their relay via Standard or Extended X10 commands.

The RF124, RF204 and RF304 may be remote controlled by addressing it by its base address or its sub address, or through groups by the commands ALL LIGHTS ON, ALL LIGHTS OFF, or ALL UNITS OFF. These global commands must be configured.

The RF124 will transmit the current relay status when requested.

A status LED verifies power to unit, and guides simple configuring procedure.


ACT RF234 A10, 208/240VAC, 50/60Hz, 20A, Fixture Module, Isolated Contact

ACT RF234 A10, 208/240VAC, 50/60Hz, 20A, Fixture Module, Isolated Contact



ACT RF234-DIN A10, 208/240VAC, 50/60Hz 20A, Fixture Module, Isolated Contact, DIN clips

ACT RF234-DIN A10, 208/240VAC, 50/60Hz 20A, Fixture Module, Isolated Contact, DIN clips



ACT RF300 277VAC, 5A, Fixture Module

ACT RF300 277VAC, 5A, Fixture Module



ACT RF310 277VAC, 20A, Fixture Module

ACT RF310 277VAC, 20A, Fixture Module



ACT RF324 A10, 277VAC, 20A, Fixture Module, Isolated Contact

ACT RF324 A10, 277VAC, 20A, Fixture Module, Isolated Contact



ACT RI104 A10, 120VAC, 20A, 4 Relay Output Receiver (cover optional)

ACT RI104 A10, 120VAC, 20A, 4 Relay Output Receiver (cover optional)



ACT RI223 208/240VAC, 20A, SP, Isolated Contact

ACT RI223 208/240VAC, 20A, SP, Isolated Contact



ACT RI304 A10, 277VAC, 20A, 4 Relay Output Receiver (cover optional)