Home View Cart Contact Us Sitemap Order Status

Access Control
Alarm Monitoring
Alarm System FAQ
Anti-Theft Devices
Audio Monitoring - Louroe
Biometrics
Burglar Alarm System Packages
Burglar Alarm Systems
CCTV Video Surveillance
Central Station Equipment
Central Vacuum
Document Center
Driveway Alarms
Entertainment Systems
Extreme CCTV
Fiber Optics
Fire Alarm Systems
Gas Detectors & Alarms
GE Security
Home Automation
Intercom Systems
Locksmith Supplies
Marine Alarms
Networks & Communications
On-Q Home
Other Stuff
Personal Emergency Response
Power Supplies
Professional Audio
Sensors and Detectors
Sirens, Strobes & Horns
Structured Wiring
Telephone Systems
Tools & Test Equipment
Wire & Cable
Z-Wave Home Automation
Shop by Brand

Fire Alarm Systems > FireLite Alarms > Addressable Detectors and Modules
Addressable Detectors and Modules

FireLite Addressable Detectors & Modules

Pull Stations
BG-12 Pull Station (FL-BG12)
BG-12 Pull Station (FL-BG12) BG-12 Pull Station (FL-BG12)

BG12LX Addressable Pull Station
BG12LX Addressable Pull Station

The Fire•Lite BG-12 Series is a cost-effective, feature-packed, non-coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of models including single- and dual-action versions.

The BG-12 Series provides Fire•Lite Fire Alarm Control Panels (FACPs), as well as other manufacturer's controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series to simple install, maintain, and operate.



BG-12SL Pull Station (FL-BG12SL) - [Special Order]
BG-12SL Pull Station (FL-BG12SL) - [Special Order]

FireLite BG-12SL Pull Station with Key Reset (FL-BG12SL)

The Fire Lite Alarms BG-12 Series is a cost-effective, feature-packed, non-coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of models including single and dual action versions.



Photoelectric Detectors

The new SD355 and SD355T Intelligent Photoelectric Detectors are used with Fire•Lite's MS-9200 and MS-9600 Addressable Fire Alarm Control Panels. Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. The SD355T offers the same features as the SD355 while adding a 135-degrees F internal thermal element.

AD355 Addressable Photoelectric Smoke & Heat Detector
AD355 Addressable Photoelectric Smoke & Heat Detector

FireLite AD355 Addressable Photoelectric Smoke & Heat Detector

Fire-Lite's AD355 Adapt detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with the addressable fire alarm control panels. The Adapt detector combines photoelectric and thermal sensing technologies designed to increases immunity to false alarms.



SD355 Addressable Smoke Detector: Photoelectric
SD355 Addressable Smoke Detector: Photoelectric

The SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).

Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z).



SD355T Addressable Smoke Detector with Heat Sensor: Photoelectric
SD355T Addressable Smoke Detector with Heat Sensor: Photoelectric

The SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C).

Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z).



Ionization Detectors

The CP355 Intelligent Ionization Detector is used with Fire•Lite's MS-9200 and MS-9600 to sense products-of-combustion and report the measured level of such products to the control panel. Since this detector is addressable, it will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.

CP355 Addressable Ionization Smoke Detector
CP355 Addressable Ionization Smoke Detector

CP355 Addressable Ionization Smoke Detector

The CP355 Addressable, low-profile (Height: 1.7 inches) plugin Ionization Detector uses a state-of-the-art ionization sensing chamber to provide open area protection and is used exclusively with Fire-Lite’s MS-9200 and MS-9600 Addressable Fire Alarm Control Panels. The ionization detector is used to sense products-of-combustion and report the measured level of such products to the fire alarm control panel. Since this detector is addressable, it will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (Part No. RA400Z).



Ionization Detectors

Fire-Lite's BEAM355 and BEAM355S are intelligent, addressable projected beam smoke detectors for protecting open areas with high and sloping ceilings, and wide-open areas, where spot-type smoke detectors are difficult to install and maintain.

BEAM355 Intelligent, Addressable Projected Beam Smoke Detector
BEAM355 Intelligent, Addressable Projected Beam Smoke Detector

FireLite BEAM355 Addressable Projected Beam Smoke Detector

The Fire·Lite BEAM355 and BEAM355S are intelligent, addressable projected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spot-type smoke detectors are difficult to install and maintain. Ideal applications are atriums, cathedral ceilings, aircraft hangers, warehouses, sporting arenas, concert halls, and enclosed parking facilities. They are compatible with the MS-9600 and MS9200UD addressable Fire Alarm Control Panels (FACPs). Installation of the single-ended reflective design is much quicker than a dual-ended projected beam detector. Alignment is easily accomplished with an optical sight and a two-digit signal strength meter incorporated into the beam detector. Listed for operation from –22ºF to 131ºF, the BEAM355 and BEAM355S are usable in open area applications where temperature extremes exceed the design limits of other types of smoke detection.



Heat Detectors

The H355/H355R Intelligent Thermal (Heat) Detectors used with Fire•Lite's MS-9600 are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open area protection.

H355 FireLite Addressable Fixed Temperature Heat Detector
H355 FireLite Addressable Fixed Temperature Heat Detector

H355A Intelligent Addressable Rate-of-Rise Heat Detector

The Fire•Lite Alarm H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open-area protection and are intended for use with Fire•Lite's MS-9600 and MS-9200UD Fire Alarm Control Panels (FACPs).



H355R FireLite Addressable Rate-of-Rise Heat Detector
H355R FireLite Addressable Rate-of-Rise Heat Detector

H355A Intelligent Addressable Rate-of-Rise Heat Detector

The Fire•Lite Alarm H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open-area protection and are intended for use with Fire•Lite's MS-9600 and MS-9200UD Fire Alarm Control Panels (FACPs).



Duct Detectors

The D350PL/D350RPL Intelligent Photoelectric Duct Detectors are used with the Fire•Lite MS-9600 and MS-9200 addressable fire alarm control panels. The D350RPL offers the same features as the D350PL while adding a Form-C relay.

D350PL Addressable Duct Smoke Detector: Photoelectric
D350PL Addressable Duct Smoke Detector: Photoelectric

DP350PL Addressable Duct Smoke Detector: Protoelectric

The new D350P and D350RP addressable photoelectric duct smoke detectors are used exclusively with the Fire•Lite MS-9200 and MS-9600 addressable fire alarm control panels. Since these duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. The D350RP offers the same features as the D350P while adding a Form-C relay.



D350RPL Addressable Duct Smoke Detector: Photoelectric with Relay
D350RPL Addressable Duct Smoke Detector: Photoelectric with Relay

DP350RPL Addressable Duct Smoke Detector: Protoelectric with Auxiliary Relay

The new D350PL and D350RPL addressable photoelectric duct smoke detectors are used exclusively with the Fire•Lite MS-9200 and MS-9600 addressable fire alarm control panels. Since these duct detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. The D350RP offers the same features as the D350P while adding a Form-C relay.



RTS451 Remote Test Station

RTS451 Remote Test Station



RTS451KEY Remote Test Station, Key Operated

RTS451KEY Remote Test Station, Key Operated



RA400Z Remote Annunciator for Duct Smoke Detector

RA400Z Remote Annunciator for Duct Smoke Detector



Monitor Modules
TThe MMF-300 Series and MDF-300 Addressable Monitor Modules are used with Fire•Lite's MS-9200 and MS-9600. These addressable modules provide Initiating Device Circuits that monitor normally-open contact alarm initiating devices, and two and four-wire detectors.
MDF-300: Monitor Module, Dual, Two Class B Circuits
MDF-300: Monitor Module, Dual, Two Class B Circuits

FireLite MDF-300 Dual Monitor Module

The MDF-300 Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED.



MMF-300 Addressable Monitor Module
MMF-300 Addressable Monitor Module

MMF-300 Addressable Monitor Module

Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices or other normally open, dry contact alarm activation devices.



MMF-301 Miniature Monitor Module
MMF-301 Miniature Monitor Module

MMF-301 Addressable Miniature Monitor Module

The MMF-301 is a miniature monitor module used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to be mounted in a single-gang box behind the device it is monitoring.



MMF-302 Interface Module
MMF-302 Interface Module

FireLite MMF-302 Interface Module

The MMF-302 Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor twowire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302 has a panel-controlled LED indicator and can be used to replace M302 modules in existing systems.



Isolator Module
I300 Isolator Module
I300 Isolator Module

FireLite I300 Fault Isolator Module

Fire-Lite's I300(A) Fault Isolator Module is used with the MS-9050UD, MS-9200UDLS, and MS-9600 to protect the system against wire-to-wire short circuits on the SLC loop. The I300(A) should be placed between each device on the SLC loop, to isolate a short-circuit problem between the modules. It is required for true Style 7 operation so that other devices can continue to operate normally in the event of a short-circuit on the SLC.



Relay Modules
CRF-300 Addressable Relay Module
CRF-300 Addressable Relay Module

FireLite CRF-300 Addressable Relay Module

The CRF-300 Addressable Relay Module provides the MS-9200 and MS-9600 systems with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door holders, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis.



CRF-300 Addressable Relay Module: 6 Relays
CRF-300 Addressable Relay Module: 6 Relays

Fire-Lite CRF-300-6 Six Relay Addressable Module

Fire-Lite's CRF-300-6 six relay control module provides an intelligent alarm system with six Form-C relays.