60-562-04 Advent Commercial 132-Zone Burglary System Control Panel
The Advent Commercial Burglary system delivers advanced hardwire/wireless burglary protection for both new and existing commercial burglary alarm installations. The system is easy to install and simple to use. The system is available in two models:
- 60-562-01 has 250 zones, 8 partitions, and up to 250 users
- 60-562-04 has 132 zones, 4 partitions, and up to 100 users
The Advent Commercial Burglary system is suited for large applications or where future expansion may be required.
High Standards
The panel comes standard with 6 general purpose inputs/outputs, one 2 wire smoke loop (12 or 24 volt) and one additional general purpose input zone. Advent auxiliary power output provides 5 amps @ 12 VDC for power to bus devices and other system peripherals. All system events are stored in a 2,048-event history buffer.
Easy Expansion
Optional SnapCards™ add system input and output capabilities. SnapCards (two per panel) connect easily to the panel circuit board inside the cabinet for a clutter-free, professional installation. Optional SuperBus® 2000 modules add even more system input and output capabilities, such as dual phone line capability, 4-relay output, on-site printer, RF transceiver, and more.
Effortless Programming
Conduct quick and easy on-site programming with alphanumeric touchpads and a menudriven text interface. Or use Advent Downloader software.
Standard Features
- Six general purpose inputs/outputs, one additional general purpose input zone, one 2 wire smoke loop (12 or 24 volt)
- Supports up to 132 or 250 (depending on model) supervised, hardwire or wireless zones
- 78 pre-defined zone configuration types
- 4 or 8 (depending on model) partitions – two account numbers per partition; 32 shared schedules per partition
- 100 or 250 (depending on model) user-programmable access codes (4-6 digit lengths allowed)
- One supervised voice status/alarm output; One dry contact relay output
- 800+ word vocabulary for voice and display
- 12 VDC, 5 amp auxiliary power output
- On- and off-site telephone access with digitized-voice feedback
- Dual SuperBus Ports – support up to 62 bus devices (31 per port)
- 2,048 event buffer with time and date stamp, can be uploaded
- Contact ID™reporting format
- Up to 16 alphanumeric pagers
- Long Range Radio (LORRA); pre-programmed, on-board header
- Network buddy system
- Programming can be downloaded using ITI Advent Downloader
- Flash memory, downloadable upgrades
Expansion Options
- SuperBus 2000 RF Transceiver (up to 5) – works with all ITI crystal, wireless Learn Mode™ sensors and touchpads
- SuperBus 2000 Dual Phone Line Module
- SuperBus 2000 Printer Module
- SuperBus 2000 8-Zone Input Module
- SuperBus 2000 4-Relay Output Module
- 4 Relay Output SnapCard
- 8Z Hardwire Input SnapCard
- 4Z/2 Output SnapCard
- 24V SnapCard (check for availability)
Specifications
- Power Supply
- Required Transformer:
– US 24 VAC, Class II Single Tap 100 VA or Class I Single Tap100 VA
– Canada 24 VAC, Class II Single Tap 120 VA or Class I Single Tap120 VA
- Backup Battery: 12 VDC, 17.2 - 18.0 Ah rechargeable, sealed, lead-acid (up to 3 batteries, additional enclosure required for third battery)
- Battery Backup Time Minimum 24 hours (depends on load and number of backup batteries installed)
- Battery Test Every 4 hours (default) or 24 hours
- Auxiliary Power 12 VDC, 5-amp built-in current limiting circuitry: SuperBus outputs limited to 650 mA each, long-range radio output limited to 250 mA
- Telephone/Modem
- Dialing DTMF or pulse
- Modem Up to 14,400 bps, Bell 103, Bell 212A, V.32bis, V.32, V.22bis, V.22, V.23, V.21, V.42bis
- Telephone Interface Line seizure relay, DTMF phone control, line supervision
- Inputs/Outputs/Connections
- General Purpose Inputs/Outputs 6 built-in; 1 additional built-in input only; up to 132 or 250 (depending on model) input zones total using optional SnapCards and SuperBus 2000 modules
- 2-Wire Smoke Loops 1 (12- or 24- VDC); up to 20 devices (24 VDC option requires additional snapcard)
- Voice Output 25 Watts, 4-8 Ohm speaker, supervised
- Interior Siren Output Open collector, 150 mA maximum, 13.8 VDC maximum
- Exterior Siren Output N.O
- Relay contacts, 4.0A maximum at 24 VDC, 4.0A maximum at 24 VAC, 1.0A maximum at 70 VAC maximum
- Auxiliary Power Outputs Regulated 12 VDC, 5 A
- SuperBus Ports 2 – up to 31 modules per port
- Long Range Radio Preprogrammed, on-board header
- Environmental
- Operating Temperature 32º to 120º F (0º to 49º C)
- Up to 140º F or 60º C under temporary conditions.
- Storage Temperature -30º to 140º F (-34º to 60º C)
- Maximum Humidity 90% relative humidity, noncondensing
Approvals/Listings
- FCC Part 15 and 68
- UL 365: Grade A, AA Police Connected Burglar Alarm Units and Systems
- UL 609: Local Burglar Alarm Units and System
- UL 985: Household Fire Warning System Units
- UL 1023: Household Burglar Alarm Units and System
- UL 1610: Central Station Burglar Alarm System Units
- UL 1635: Digital Alarm Communicator Systems
- UL 1637: Home Health Care Signaling Equipment
- CSFM California State Fire Marshall
- DOD Sensitive Compartment Information Fac (applied for)
- Complies with NFPA 72 for Fire Alarm Code
Physical Description
- Color Light gray
- Material 16 gauge steel
- Dimensions 21.5 x 14.75 x 5 inches
|
|
|
| |
 |
Product Reviews
|
|