Home View Cart Contact Us Sitemap Order Status

Access Control
Alarm Monitoring
Alarm System FAQ
Anti-Theft Devices
Audio Monitoring - Louroe
Biometrics
Burglar Alarm System Packages
Burglar Alarm Systems
CCTV Video Surveillance
Central Station Equipment
Central Vacuum
Document Center
Driveway Alarms
Entertainment Systems
Extreme CCTV
Fiber Optics
Fire Alarm Systems
Gas Detectors & Alarms
GE Security
Home Automation
Intercom Systems
Locksmith Supplies
Marine Alarms
On-Q Home
Other Stuff
Power Supplies
Professional Audio
Sensors and Detectors
Sirens, Strobes & Horns
Structured Wiring
Telephone Systems
Tools & Test Equipment
Warrantees
Wire & Cable
Z-Wave Home Automation
Discontinued Products
Shop by Brand

Burglar Alarm System Packages > Ademco Vista-50P
Ademco Vista-50P

Honeywell / Ademco Vista-50P

ADEMCO's VISTA-50P control panel provides the flexibility of up to eight independent partitions with the economy of a single control. Nine hardwired zones standard. Expandable to 87 total zones. Eight partitions standard. 75 user codes work in all partitions. Seven authority levels. 224 event memory log/printer option. Four trigger outputs. 5800 wireless compatibility. Supports two-wire multiplex. Scheduling of events (real time clock). Keypad macro features. Master console option for viewing all partitions at a glance. Common lobby logic. Fast downloading. Supports up to 16 relays and/or X-10. Quick start programming. False alarm features. UL Commercial Burglary listed (VISTA-50PUL).


Honeywell 4208U V-Plex Universal Eight Zone Remote Point Module

V-Plex™ Universal Eight Zone Remote Point Module

The ADEMCO 4208U Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on ADEMCO controls that support V-Plex polling loop devices.

Features

  • Can be optionally powered from an external DC power supply to reduce the amount of current draw from the polling loop
  • Uniquely identifies eight EOLR supervised zones (all zones use 10K resistors, supplied)
  • DIP Switches can be used to set zone numbers or serial numbers
  • When used in the serial number mode, each serial number in the selected group can be assigned to any zone number
  • Loops A & B can be programmed for fast (10msec) response
  • Provides cover tamper protection, which may be enabled or disabled via on-board DIP Switches
Specifications
  • Physical:
    Width: 6-7/16" (163mm)
    Height: 4-1/4" (108mm)
    Depth: 1-1/4" (32mm)
  • Electrical:
    Polling Loop input: 7.3 - 14VDC range
    Current draw: 28.6mA max. External power and polling loop
    See chart below.
  • External Power Input (optional): 12VDC @ 28mA (from control panel’s auxiliary power)
  • Sensor Loop Response :
    Slow: 400 msec (all loops)
    Fast: 10msec (option for loops A and B)
  • Sensor Loop Current :
    Polling loop input = 11VDC, no external power input):
    0.52mA (normal)
    1.3mA (shorted)
  • Sensor Loop Max. Current : Up to 300 ohms of wire resistance + 10K EOLR
  • Agency Listings :
    UL 985 Household Fire
    UL 1023 Household Burglary
    UL 609 Commercial Burglary
    UL 864 Commercial Fire
    CSFM
    FM
    CUL
    CE (requires #N6361)

Power Input Source
(Input Voltage: 11-14VDC)

Current Draw  (all zones shorted)

From Polling Loop

From External Power

Polling Loop Only

33.6mA 

N/A

Polling Loop and
External Power Input

0.6mA

33mA

For UL Listed Commercial Fire Usage:
Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately).
For UL Listed Commercial Burglary Usage:
Use N.O. or N.C. contacts. Supervise using EOLRs supplied.
Ordering Information
Part No. Description
4208U 8 Zone Expander
 
Honeywell 4208U V-Plex Universal Eight Zone Remote Point Module
[Printable View]