Paradox 469 Motion Detector Mounting Bracket
|
|
|
|

710 ParaVox Voice Dialer
- Provides any control panel with remote voice and pager messaging
- 4 zone inputs and 2 PGM outputs
- 4 telephone and 4 pager numbers
- 1 installer and 4 user PINs
- Voice message length: 4 X 15 seconds or 2 X 30 seconds
- Programmed through a telephone
- Available in English, Hungarian, Italian, Mandarin and Spanish
|
|
|
|
|

Paradox APR-ZX8 8-Zone Expansion Module
|
|
|
|

Paradox DGP2-PS17 Power Supply Module
|
|
|
|

Paradox MAGELLAN IP100 Internet Module
- Control and monitor an E55, MG5000, MG5050, Spectra SP or EVO control panel through an IP network (LAN/WAN/Internet)
- Use WinLoad to access your system through the Internet
- Receive notification of system alarms via email
- Arm/disarm individual partitions via web browser
- View live status of all zones and partitions (i.e. open/close, arm/disarm, troubles and alarms) via web browser
- Upgrade the firmware of the IP100 using the IP Exploring Tools through the Internet
- DNS service available for dynamic IP address
- Very low bandwidth consumption
- Data sent and received using 128-bit (MD5 and RC4) or 256-bit (AES) data encryption
- Two-way dynamic authentication
|
|
|
|
|

Paradox LR-1 Long Range Lens
|
|
|
|

|
SPC-ZX4 4-Zone Expansion Module from Paradox
- Add 4 zones
- Use zone input as an anti-tamper switch input
|
|
|
|
|

|
APR3-ZX4 4-Zone Expansion Module from Paradox
- Add 4 zones
- Use zone input as an anti-tamper switch input
- Auto-Panel Recognition
|
|
|
|
|

|
SPC-ZX8 8-Zone Expansion Module from Paradox
- Add 8 zones
- 1 PGM output
- Use zone input as an anti-tamper switch input
|
|
|
|
|

|
APR3-HUB2 Hub and Bus Isolator from Paradox
- Divide the bus into two completely isolated outputs (if one output fails, the other will continue to function)
- One input port, 2 completely isolated output ports
- Each output port provides communications up to 75m (250ft)
|
|
|
|
|

|
PMC-4 Hand-Held Plug-in Memory Key from Paradox
- Download or upload control panel programming in less than 5 seconds
- Connect directly to memory connector on the control panel
- No need for a telephone line, PC or any other peripheral device
|
|
|
|
|

|
ADP-1 Telephone Line Adapter from Paradox
- Simulate a telephone line for on-site uploading and downloading
- Direct connection from the PC's modem to the control panel's dialer
- 300 baud communication
|
|
|
|
|

|
APR3-ZX8 8-Zone Expansion Module from Paradox
- Add 8 zones
- 1 PGM output
- Use zone input as an anti-tamper switch input
- Auto-Panel Recognition
|
|
|
|
|

|
APR3-PGM4 4-PGM Expansion Module from Paradox
- 4 fully programmable 5A relay outputs
- Deactivate PGM after event or timer
|
|
|
|
|

|
APR3-ADM2 InTouch Voice-Assisted Arm/Disarm Module from Paradox
- Arm, disarm, control on-board PGM and verify system status via telephone
- Clear and concise voice prompts
- Available in Czech, English, French, Greek, Italian, Portuguese, Spanish and Turkish
- 1 PGM output
|
|
|
|
|

|
APR3-PRT1 Printer Module from Paradox
- Automatically/manually print reports of zones/system events via a printer and/or PC
- Parallel and serial port connectors
- Assign to any or all partitions
- 1 PGM output
- Available in English or Spanish
|
|
|
|
|

|
DGP2-ZX4 4-Zone Expansion Plug-in Device from Paradox
- Connects directly on main board
- 4 addressable zones (8 with ATZ zone doubling feature)
- Set a different input speed for each zone (up to 7.65 seconds)
- Supported by DigiplexNE (DGP-NE96)
|
|
|
|
|

|
DGP2-TM1 Real-Time Plug-in Device from Paradox
- Connects directly on main board
- Keeps time and date during a complete power failure
- 8-year battery life expectancy (battery included)
- Not required with DigiplexNE (DGP-NE96)
|
|
|
|
|

|
306 Direct Connect Interface from Paradox
- Enables main board to communicate with a PC at 8m (25ft)
- Connect from main board’s serial port connector to PC’s serial port (DB-9)
- 38.4k baud communication (DigiplexNE) or 19.2k baud communication (Digiplex)
|
|
|
|
|

|
UDS-2000 WinLoad Installer Upload/Download Software from Paradox
- User-friendly programming and monitoring of Spectra, Magellan, Digiplex and DigiplexNE
- Remote or on-site upload/download using most standard modems at 300 baud
- On-site (local) uploading and downloading at 57.6k baud (Magellan), 38.4k baud
(EVO96) or 19.2k baud (DGP-848) using a 306USB Direct Connect Interface (60m/
200ft) or a CONV3USB Converter (300m/1000ft)
- New in-field upgrading feature that allows WinLoad to upgrade the firmware of
certain control panels/modules via a 306USB interface or a CONV3USB converter
- Multiple users, groups and databases
- Network compatible
- Advanced printing of event reports and zone/user programming
- Supports several languages simultaneously (available in English, Spanish, Chinese,
Czech, French, Hebrew, Hungarian, Italian, Polish, Portuguese, Russian, Serbo-
Croatian, Slovak, Swedish and Turkish)
|
|
|
|
|

|
UIP-256 Universal In-Field Programmer from Paradox
- Upgrade Magellan and Grafica firmware locally in the field
- Includes proprietary PC software, cables to interconnect a Magellan console or a
Grafica keypad and a PC, and two 9V batteries
- The supplied PC software retrieves the latest Magellan or Grafica update file
(firmware) from our website and then updates the Magellan console or the Grafica
keypad
- Currently supports Magellan V1.10 or higher and Grafica version 1.21 or higher, but
will support other Paradox products when possible in the future
|
|
|
|
|

DGP2-ACM1P Access Control Module
- Connections for card reader, REX, door contact and lock output
- Automatic unlocking schedule
- Door left open and door forced options
- Door unlock and extended delay timers
- Grant access via card and/or access code (supports CR-R885-BL PosiPIN reader)
- Unlock door manually with button or PGM event
- Built-in 1.5A switching power supply (supervised only if used)
- Supports 26-bit Wiegand card readers
- Includes 20cm x 25.5cm x 7.6cm (8" x 10" x 3") metal box
- Version 2.0 of the Access Control Module (DGP2-ACM1P) includes the following new features:
- Unlock Door On Fire Alarm option
- Safe Mode option (during a communication loss, the access control door connected to the module can grant access to up to 4 specified cards
|
|
|
|
|

|
|