Cartell CF-2C Driveway System: Sound & Lights
This control unit with dual timed output includes floodlight control with full features. Field adjustments include: entry delay, floodlight time, exit delay, photocell sensitivity, re-trigger hold-off, annunciator time, probe sensitivity, and transient suppressor.
- Includes CA-5 plug-in transformer and FC-6 photocell daylight block.
- Use with CT-6 probe.
- Accommodates annunciators: FC-9, CT-8, CT-8A, CT-9A, CT-11.
- Case and circuit board may be purchased separately.
- CT-6 sensor probe with custom amount of direct burial cable attached (up to 3,000 feet)
- Annunciator: FC-9 (full function annunciator custom made for CF-2C), CT-8, CT-8A, CT-9A and/or CT-11; or you may use your own sounder.
- Stand-alone system where annunciation and lights are needed to alert that a vehicle is approaching. Integrate with security and home automation systems.
- Also activates CCTV, pager-transmitters, and transmitters.
- Use line carrier technology (X-10, Leviton, etc.) to avoid hard-wiring of lights.
Features
- Covers 12 foot wide driveway when sensor probe buried beside drive
- Single-zone system
- Dual timed output
- 15 amp circuit operates up to 1800 watts of lights
- Accommodates 100 sensor probes
- Accommodates twelve annunciators
- Adjustable probe sensitivity
- Adjustable relay time
- Adjustable annunciator time
- Adjustable floodlight delay time
- Adjustable floodlight time
- Adjustable photocell sensitivity
- Adjustable FC-9 exit delay
- Manual trip test button
- Re trigger hold-off
- Transient suppression
- Built-in battery charger to use to power annunciators during power outage (battery not included)
- 12 volt transformer included
- Photocell light-block included (keeps lights from operating in daylight)
Benefits
- Detects 100 locations
- Annunciates twelve locations
- Turns on up to 1800 watts of floodlights
- Acts as a trigger to activate transmitters
- Used with CT-6 probe, detects moving vehicles
- Used with CT-6 probe, protects stationary vehicles
- Used with CT-6 probe, signals security guard
Specifications
| Power Required: | 12 VAC or 12-15 VDC |
| Standby Current: | 35 mA |
| Alarm Current: | 180 mA max. with 1 FC-9 or 1 CT-8 |
| Relay Contact Rating: | Double Pole, Double Throw |
| 1st Pole: | 12 VDC, 200 mA for remotes |
| 2nd Pole: | SPDT, 5 amps, 30 VDC |
| Relay Time: | 1/2 to 30 seconds |
| Floodlight Contact Rating: | SPST, 15 amp, 125 VAC CSA (1800 watts) |
| Floodlight Time: | 15 seconds to 15 minutes |
| Floodlight Delay: | 1 second to 2 1/2 minutes |
| Battery Charger: | 13.5 VDC, 5 mA minimum charge (with voltage cut-off) |
| Temperature Range: | 0º F - 140º F |
| Dimensions (complete unit): | 7 1/2 in. x 12 3/4 in. x 3 in |
| Dimensions (board only): | 7 1/4 in. x 4 1/4 in. |
| Weight (complete unit): | 5 lbs |
|
|
|
| |
 |
|
|