Home View Cart Contact Us Sitemap Order Status

Access Control
Alarm Monitoring
Alarm System FAQ
Anti-Theft Devices
Audio Monitoring - Louroe
Biometrics
Burglar Alarm System Packages
Burglar Alarm Systems
CCTV Video Surveillance
Central Station Equipment
Central Vacuum
Document Center
Driveway Alarms
Entertainment Systems
Extreme CCTV
Fiber Optics
Fire Alarm Systems
Gas Detectors & Alarms
GE Security
Home Automation
Intercom Systems
Locksmith Supplies
Marine Alarms
On-Q Home
Other Stuff
Power Supplies
Professional Audio
Sensors and Detectors
Sirens, Strobes & Horns
Structured Wiring
Telephone Systems
Tools & Test Equipment
Warrantees
Wire & Cable
Z-Wave Home Automation
Discontinued Products
Shop by Brand

Burglar Alarm Systems > Honeywell / Ademco > Control Panels
Control Panels

Ademco Vista Control Panels

Vista-15P Wired/Wireless Alarm Control Panel

VISTA-15P from Ademco

The versatile VISTA-15P is the ideal choice for any residential installation. Hardwired expansion, two-wire smoke detectors, scheduling options and a host of end-user and installer features separate the VISTA-15P from all other six-zone panels – offering you and your customers the most panel for the dollar.


Specifications | Ordering Information

Features

  • Six on-board hardwired zones
    – Hardwire expansion up to 22 zones
    – Wireless expansion up to 26 zones
  • Eight independent keyfob zones allow wireless keys to be programmed without using any of the 22 zones
  • Six on-board hardwired zones standard
  • Expandable to 32 total zones when used with hardwired and/or wireless expansion modules
  • Hardwire expansion up to 16 zones Wireless expansion up to 26 zones
  • Wireless Keys can be programmed without using zones
  • Eight output devices
    – Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or
    – X-10 ฎ devices (when used with a 4300 Transformer)
  • Two low current on-board trigger outputs
  • 50 Event Log viewable at system keypads with time/date stamp
  • 32 system user codes
  • Two installer configurable zone types allows the installer to "create custom zone types" by assigning all zone attributes
  • Multiple actions on output devices depending on system "state"
    – Turns light off when system arms
    – Turns same lights on when system disarms
    – Flashes same lights when system is in alarm
  • Built-in phone line cut monitor with programmable delay and annunciation options
    – Display on system keypads
    – Trigger local sounders
    – Trigger system bell
  • Supports four-wire, and up to 16 two-wire smokes
    – Works with Sentrol CleanMe™ maintenance signal

Valuable End-User Features

  • Now viewable on system keypads:
    – Exit countdown
    – Time and date display*
    – Event log*
  • Auto keypad backlighting on entry
  • Keyswitch arming
  • Programmable macro buttons and single-button arming
  • A variety of wireless remote controls for single-button operation
  • User Scheduling
    – Automatically activates X-10 and relays at programmed times
    – Latchkey reports to pagers
    – Auto arm/disarm
    – "User access" time windows
  • Supports up to two numeric pagers
  • VIP Module allows system control from any touchtone phone
  • Chime by zone
*Requires custom alpha keypad

UL approved for ANSI/SIA CP-01-2000

Security Dealer Features

  • False alarm prevention features help reduce false alarms
  • Automatic System Load Shed
    – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
  • Dynamic Signaling
    – Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet Radio

Specifications
(Return to top)

Electrical

  • Aux. power 12VDC, 600mA maximum
  • Seven hour standby at 400mA aux. load with four amp hour battery
  • 16.5VAC/25VA transformer
  • Alarm output 12VDC, 2.0 amps maximum
  • For UL installations, combined aux. and alarm output cannot exceed 700mA

Output Control

  • Supports a maximum of eight output devices (combination of relays and/or X-10) plus two onboard triggers

Zones

  • Six hardwired zones
  • Selectable response: 10msec, 350msec, 750msec
  • 16 selectable zone types plus two configurable zone types
  • Programmable swinger suppression

Expansion Devices

  • 4219 – Eight hardwired zones – 16mA
  • 4204 – Up to four relays – 15mA standby (each active relay draws an additional 40mA)
  • 4229 – Eight hardwired zones and two relays – 36mA (each active relay draws an additional 40mA)

Accessories

  • 4286 VIP Voice Module – 220mA
  • 5881ENL supports up to eight zones – 60mA, 5881ENM supports up to 16 zones – 50mA, 5881ENH supports up to 26 zones – 50mA
  • 5883 Transceiver supports up to 26 zones – 80mA
  • Supports Eagle 1225 and 1221 boards

Keypads

  • 6160 Custom English (required for programming) – 100mA
  • 6150 Fixed English LCD – 85mA/40mA

Agency Listings

  • UL Residential Fire, Burglary and CSFM

Smoke Detectors

  • Supports up to 16 two-wire smoke detectors
  • Supports four-wire smoke detectors

Communications

  • Touchtone or pulse
  • Formats supported
    – ADEMCO Contact ID
    – ADEMCO 4 + 2 Express
    – ADEMCO low speed
    – Sescoa/Radionics
  • 3 + 1, 4 + 1 and 4 + 2 reporting
  • Reporting capabilities
    – Split
    – Dual
    – Split/Dual – True dial tone detection
  • Low battery reports 11.2 – 11.6VDC
  • AC loss and restoral reporting supported

Ordering Information