VISTA-15P from Ademco
The versatile VISTA-15P is the ideal choice for any residential installation. Hardwired expansion, two-wire smoke detectors, scheduling options and a host of end-user and installer features separate the VISTA-15P from all other six-zone panels offering you and your customers the most panel for the dollar.
|
Specifications | Ordering Information
|
|
|
Features
- Six on-board hardwired zones
Hardwire expansion up to 22 zones
Wireless expansion up to 26 zones
- Eight independent keyfob zones allow wireless keys to be programmed without using any of the 22 zones
- Six on-board hardwired zones standard
- Expandable to 32 total zones when used with hardwired and/or wireless expansion modules
- Hardwire expansion up to 16 zones Wireless expansion up to 26 zones
- Wireless Keys can be programmed without using zones
- Eight output devices
Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or
X-10 ฎ devices (when used with a 4300 Transformer)
- Two low current on-board trigger outputs
- 50 Event Log viewable at system keypads with time/date stamp
- 32 system user codes
- Two installer configurable zone types allows the installer to "create custom zone types" by assigning all zone attributes
- Multiple actions on output devices depending on system "state"
Turns light off when system arms
Turns same lights on when system disarms
Flashes same lights when system is in alarm
- Built-in phone line cut monitor with programmable delay and annunciation options
Display on system keypads
Trigger local sounders
Trigger system bell
- Supports four-wire, and up to 16 two-wire smokes
Works with Sentrol CleanMe maintenance signal
Valuable End-User Features
- Now viewable on system keypads:
Exit countdown
Time and date display*
Event log*
- Auto keypad backlighting on entry
- Keyswitch arming
- Programmable macro buttons and single-button arming
- A variety of wireless remote controls for single-button operation
- User Scheduling
Automatically activates X-10 and relays at programmed times
Latchkey reports to pagers
Auto arm/disarm
"User access" time windows
- Supports up to two numeric pagers
- VIP Module allows system control from any touchtone phone
- Chime by zone
*Requires custom alpha keypad
UL approved for ANSI/SIA CP-01-2000
Security Dealer Features
- False alarm prevention features help reduce false alarms
- Automatic System Load Shed
During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
- Dynamic Signaling
Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet Radio
Specifications
(Return to top)
Electrical
- Aux. power 12VDC, 600mA maximum
- Seven hour standby at 400mA aux. load with four amp hour battery
- 16.5VAC/25VA transformer
- Alarm output 12VDC, 2.0 amps maximum
- For UL installations, combined aux. and alarm output cannot exceed 700mA
Output Control
- Supports a maximum of eight output devices (combination of relays and/or X-10) plus two onboard triggers
Zones
- Six hardwired zones
- Selectable response: 10msec, 350msec, 750msec
- 16 selectable zone types plus two configurable zone types
- Programmable swinger suppression
Expansion Devices
- 4219 Eight hardwired zones 16mA
- 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA)
- 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA)
Accessories
- 4286 VIP Voice Module 220mA
- 5881ENL supports up to eight zones 60mA, 5881ENM supports up to 16 zones 50mA, 5881ENH supports up to 26 zones 50mA
- 5883 Transceiver supports up to 26 zones 80mA
- Supports Eagle 1225 and 1221 boards
Keypads
- 6160 Custom English (required for programming) 100mA
- 6150 Fixed English LCD 85mA/40mA
Agency Listings
- UL Residential Fire, Burglary and CSFM
Smoke Detectors
- Supports up to 16 two-wire smoke detectors
- Supports four-wire smoke detectors
Communications
- Touchtone or pulse
- Formats supported
ADEMCO Contact ID
ADEMCO 4 + 2 Express
ADEMCO low speed
Sescoa/Radionics
- 3 + 1, 4 + 1 and 4 + 2 reporting
- Reporting capabilities
Split
Dual
Split/Dual True dial tone detection
- Low battery reports 11.2 11.6VDC
- AC loss and restoral reporting supported
|
|
|
| |
 |
|
|