Fire Alarm Systems > Silent Knight Fire Alarms > Conventional Fire Alarm Controls
Conventional Fire Alarm Controls

Silent Knight
Conventional Fire Alarm Controls

5104 Fire Control Communicator: 6 Zones, 24 Volt

Model 5104 Fire Control Communicator

NEW! (Now six zones)

We know digital communication. And, with hundreds of thousands of our communicators worldwide, it shows.

The Silent Knight Model 5104 is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls.

As a stand-alone unit, it can be used to monitor:

  • Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions.
  • Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours).
  • Dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each.

The Model 5104 is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 45 seconds, it will automatically switch to the other to report the failure.

The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal fourwire contact type, for automatic fire detection applications.

Features
  • UL 864 Listed for NFPA 72 Central Station and Remote Supervising Station Fire Alarm System Service.
  • Can be used as a stand-alone or as UDACT.
  • Six fully supervised inputs: one Class A Subgroup Style D input, and three Class B Subgroup B inputs.
  • Downloadable for remote programming.
  • Fuseless overload protection with automatic reset circuitry and fault indicators - eliminates the cause of most field calls.
  • Dual phone line interface.
  • Automatic self test every 24 hours with report sent to central station.
  • Reports in SIA and most major communications formats.
  • 60 hours of standby power.
  • Operates on loop start phase lines ahead of the building PBX system.
  • A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes).
Downloads:
 
5104 Fire Control Communicator: 6 Zones, 24 Volt
[Printable View]