MS-2 Two-Zone Fire Alarm Control Panel
FireLite's MS-2 and MS-4 Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-2 is compatible with the new I3 smoke detectors from System Sensor, and provide such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances.. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
The MS-2 also is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. See the FireLite Device Compatibility Document ( Doc. No. 15384) for a complete list of compatible devices.
Features:
- Two Style B (Class B) IDCs (Initiating Device Circuits) .
- One Style Y (Class B) NAC (Notification Appliance Circuit).
- 24VDC.
- I3 Technology features:
Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust accumulation.
Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA72, 7-3.2.1).
Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminents settling in the chamber.
Wireless handheld sensitivity meter eliminates the need for voltemeters, magnets and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication.
Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing.
Special test protocol and LED indication allows quick test of all detectors without need for a ladder.
- NAC synchronization features:
Provides synchronization of standard ANSI audible signals as required by NFPA 72 (3-8.4.1.2.3).
Provides synchronization of ADA compliant strobes per NFPA 72 (4-4.4.1).
Selectable for System Sensor, Wheelock and Gentex protocols.
Selective Silence feature allows manual silence of horns while strobes continue to flash on the same NAC.
- Silent or Audible Walk Test operation mode commanded from the front keypad, with automatic return to normal after 1 hour of inactivity.
- Alarm verification selectable per zone.
- Each zone may be programmed for supervisory or fire, with separate red and yellow LEDs.
- Disable switches provided per zone.
- NACs programmable for:
Silence Inhibit
Auto Silence
Strobe Synchronization
Selective Silence (horn-strobe mute)
Temporal or Steady signal
Silenceable or Nonsilenceable
- Form-C Alarm and Trouble relays.
- 3.0 amps total useable current .
- Optional dress panel (part no. DP-MS2/4).
- Control buttons:
ACK (Acknowledge)
Alarm Silence
Reset
Walktest
Zone Enable/Disable (one per zone)
- LED indicators:
Fire Alarm (one per zone)
Supervisory (one per zone)
Trouble (one per zone)
Maintenance (one per zone)
AC Power
NAC Disable
Zone Disable
NAC Fault
System Trouble
Power Trouble
Walktest
Alarm Silence
Earth Fault (on circuit board)
Battery Fault (on circuit board)
Charger Fault (on circuit board)
- Piezo sounder for alarm, trouble, supervisory and maintenance.