The ESL 320A/350 Series alarms are single/multiple station photoelectric 120VAC smoke alarms. Because of its low profile, this series is ideal for use in residential occupancies, including hotels, motels and dormitories.
ESL 429 Smoke Detectors Direct Wire 2 Wire - GE Sensors
The 429 Series self-diagnostic, two-wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. They meet NFPA 72 field sensitivity testing requirements without the need for external meters.
449CRT Smoke Detector with 135º Heat Sensor: 4 Wire - GE Sensors
The 400 Series self-diagnostic, four-wire smoke detectors continually monitor their own sensitivity and operational status and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. They meet NFPA 72 field sensitivity testing requirements without the need for external meters.
449 Smoke Detectors Direct Wire 4 Wire - GE Sensors
The 400 Series self-diagnostic, four-wire smoke detectors continually monitor their own sensitivity and operational status and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. They meet NFPA 72 field sensitivity testing requirements without the need for external meters.
449CT Smoke Detector with 135º Heat Sensor: 4 Wire - GE Sensors
The 400 Series self-diagnostic, four-wire smoke detectors continually monitor their own sensitivity and operational status and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. They meet NFPA 72 field sensitivity testing requirements without the need for external meters.
The ESL 500N series 2&4 wire conventional photoelectric smoke detectors bring together trusted technology and a full line of needed features to meet the demands of every type of application. The 500N offers sounders in 2&4 wire applications, specifically to meet residential code requirements. The 521NCSXT has the added benefit of low current draw which makes it compatible with a wide variety of control panels. The ESL 500N series also offers choices for optional auxiliary relays and isolated heat sensors, not available before in the ESL 500 series. ESL is proud to offer proven technology like CleanMe®, dust compensation, field replaceable optical chambers, multi-criteria heat algorithms and self-diagnostics which are trusted by installers around the globe.
ESL 429-AT Photoelectric Smoke Detector with 135º Heat Detector and Audible Alarm
The 429 Series self-diagnostic, two-wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. They meet NFPA 72 field sensitivity testing requirements without the need for external meters.
Photoelectric Smoke Alarm for 120VAC/9VDC Single or Multiple (Tandem) Station and Specialty Applications
120VAC photoelectric smoke alarm/detector with 9VDC battery back-up as an auxiliary power source in the event of an electrical failure. Features a warning signal for low or missing battery. Applications include homes and apartments, as well as hospitals, hotels and nursing homes per UL 217, UL1730, applicable UBC/UFC and IBC/IFC Standards and NFPA 72, Chapter 2.
System Sensor’s i3™ series smoke detectors represent a significant advancement in
conventional detection. The i3 family is founded on three principles: Installation
ease, Intelligence, and Instant inspection.
The BEAM1224 is a 4-wire, single-ended, reflected type beam smoke detector that includes an 8" reflector.
System Sensor Model BEAM1224 is a 4-wire conventional projected beam smoke detector. It is uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. It is to be used with UL Listed compatible control panels only. Installation of the single-ended reflective design is much easier than the dual-ended projected beam detectors. Alignment is quickly accomplished via an optical sight and a 2-digit signal strength meter incorporated into the product. Listed for operation from –22°F to 131°F, BEAM1224 can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection.
BEAM1224S Reflected Type Beam Smoke Detector with Built-In Sensitivity Test
The BEAM1224 is a 4-wire, single-ended, reflected type beam smoke detector that includes an 8" reflector and an integral sensitivity test.
System Sensor Model BEAM1224 is a 4-wire conventional projected beam smoke detector. It is uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. It is to be used with UL Listed compatible control panels only. Installation of the single-ended reflective design is much easier than the dual-ended projected beam detectors. Alignment is quickly accomplished via an optical sight and a 2-digit signal strength meter incorporated into the product. Listed for operation from –22°F to 131°F, BEAM1224 can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection.
System Sensor 2151 Low Profile, Plug-In Photoelectric Smoke Detector
Model 2151 (photoelectric sensor) and model 2151T (photoelectric sensor with thermal) can be used with a variety of adapter bases in several wiring configurations and voltages. Other features include: low current draw, stable performance in high air velocities, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch.
System Sensor 2W-B Smoke Detector: 2-wire, I3 Series
Installation Ease. Intelligence. Instant Inspection. These are the guiding principles of System Sensor's i3 series of photoelectric smoke detectors. Designed to take conventional smoke detectors to a new level, these principles translate directly into significantly lower installation, testing and maintenance costs.
System Sensor 2WT-B Smoke Detector: 2-wire with 135-degree Thermal Sensor, I3 Series
Installation Ease. Intelligence. Instant Inspection. These are the guiding principles of System Sensor's i3 series of photoelectric smoke detectors. Designed to take conventional smoke detectors to a new level, these principles translate directly into significantly lower installation, testing and maintenance costs.
System Sensor’s i3™ series smoke detectors represent a significant advancement in
conventional detection. The i3 family is founded on three principles: Installation
ease, Intelligence, and Instant inspection.